diff options
| -rw-r--r-- | api_layers/protocols/mark10.py | 5 | ||||
| -rw-r--r-- | devices/serial_device.py | 8 |
2 files changed, 13 insertions, 0 deletions
diff --git a/api_layers/protocols/mark10.py b/api_layers/protocols/mark10.py index a209232..48ed927 100644 --- a/api_layers/protocols/mark10.py +++ b/api_layers/protocols/mark10.py @@ -44,6 +44,11 @@ class Mark10Layer(BaseProtocol): super().__init__(port, baud, poll_interval, simulate) self._unit = "N" + @property + def current_unit(self) -> str: + """Last unit suffix seen in a gauge reply (e.g. "N", "kgF").""" + return self._unit + # ── Protocol ────────────────────────────────────────────────────────── def _poll(self) -> Dict[str, float]: diff --git a/devices/serial_device.py b/devices/serial_device.py index 580421c..449956b 100644 --- a/devices/serial_device.py +++ b/devices/serial_device.py @@ -142,6 +142,14 @@ class SerialDevice(BaseDevice): raw = self._layer.read() if not raw: return {} + if self._fmt == "mark10" and hasattr(self._layer, "current_unit"): + # Gauge can be switched between lb/kgF/N/ozF on the device itself — + # keep the channel's unit in sync so new plots/pickers/CSV log + # headers pick up the currently-selected unit instead of a fixed + # default. Does not relabel the axis of an already-open plot pane. + force_ch = self.get_channel("force") + if force_ch is not None: + force_ch.unit = self._layer.current_unit if self._fmt not in _GENERIC_FORMATS: # Protocol layers already key by channel_id — pass through untouched. # (Write-only channels, e.g. CML "M1_VS", never appear in raw — correctly dropped.) |
