2026-07-29Merge branch 'fix/control-channel-direction-filter'Christian Kolset
# Conflicts: # ui/control_editor.py
2026-07-29Make Run the master stop switch; add Log button disabled/recording stylingChristian Kolset
Run/Stop previously only paused acquisition — control outputs (motor speed, switches, PWM duty) kept whatever value was last written, so stopping the run loop didn't stop a running motor. Adds ControlWidget.safe_stop() (per-widget override, default zeros the output) and ControlPanel.safe_stop_all(), called from _toggle_run's Stop branch before engine.stop(). Per-widget behavior is deliberately not uniform: - OnOffSwitch/MotorControl/PwmControl have a latched running/enabled state, so safe_stop() drives their own toggle handler (consistent UI + write in one path) and, for Motor/PWM, zeroes the slider too. - SetpointControl/AnalogOutputControl only write on an explicit user action and have no universally safe forced value (e.g. 0 isn't necessarily "off" for an arbitrary process setpoint or analog output) — Stop leaves them untouched rather than guessing. Log button: added a :disabled QSS rule so "can't log yet" reads as clearly inert rather than a duller version of the enabled look, and a 600ms blink (toggling a "recording" dynamic property the QSS keys off) while a recording is active, so it reads as live/recording rather than a static pressed button. Master Stop now calls _toggle_log(False) explicitly when forcing the button off, since QPushButton.setChecked() doesn't emit clicked — without this the blink would keep running after a master Stop even though logging itself already halted via engine.stop()'s internal stop_logging() call. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-29Hide non-writable channels from Controls picker, gate writes on enabled+writableChristian Kolset
Adds ChannelConfig.writable so the Controls editor can only bind to channels with a real write mapping (VS/MA/ME/MD/ST for CML, do*/DO for digital I/O, write_cmd-configured SCPI channels, holding-register Modbus channels) instead of read-only telemetry — this is exactly the class of mistake hit earlier (binding a motor-speed control to M1_TV instead of M1_VS). Also carries forward the enabled-channel gating for controls (hide disabled channels from the picker, block writes to them at _write() time) done alongside this investigation. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-27Fix .gitignore: remove duplicate entry for plugins/enabled.jsonChristian Kolset
2026-06-09Scripting: named signal vars, shared vars dict, control scripts, code templatesChristian Kolset
- Named variables in expressions: source channel IDs injected as Python identifiers alongside x[] (e.g. write `A0 * 2` instead of `x[0] * 2`) - Shared `vars` dict on SignalProcessor accessible from all expressions, functions, and control scripts; persisted in .labdaq profiles - Per-derived-channel `state` dict for persistent computation state in custom scripts - Control widgets gain optional on_action_script (Python snippet with value, vars, channels, math in scope); syntax-checked in editor dialog - Built-in derived kinds (derivative, rms, power, etc.) now show their Python implementation as read-only code previews; "Edit as Custom Script" converts to custom_script kind with template pre-filled Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-22Fixed saving profile to include devices and their configurationChristian Kolset
2026-04-22Added feature/create-controlsChristian Kolset
2026-04-21V13Christian Kolset
This version contains the profile feature. Allowins users to save the channels, signals and plots for specific labs.
2026-04-20V8Christian Kolset