| Age | Commit message (Collapse) | Author |
|
Superseded by ui/windows/signals_window.py; no longer imported anywhere.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
|
|
- Default ID: sig_N → CH_VN
- Default name: Signal N → Virtual Channel N
- Rename "Kind" label to "Operation"
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
|
|
- Split PipelineTab into Physical/Virtual sections via QSplitter
- Each section has independent scroll area, header, and add controls
- Add "With Respect To" control for derivative/second_derivative virtual channels: Time (dy/dt) or Channel (dy/dx)
- When Channel selected, x variable picker appears for any physical or derived channel
- signal_processor computes dy/dx using channel inputs when deriv_wrt=channel
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
|
|
- Remove redundant Signals tab from Channels window; PipelineTab is now direct content
- PipelineTab removes stale blocks when devices are removed or reconfigured
- Devices>Signals tab refreshes automatically on device add/remove/configure
- Channel name and unit edits in Devices>Signals propagate live to Channels pipeline block headers; missing blocks auto-added if channel is enabled
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
|
|
- Add missing QGroupBox import to settings_window (caused silent crash on open)
- Remove Controls tab and _controls_tab() method from settings
- Clamp child window positions to screen bounds so they don't go off-screen on Windows when main window is maximized
- Apply same screen-clamp fix to Motion Capture plugin window
- Delete example plugin; disable it in enabled.json
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
|
|
Tracks a user-selected point via webcam (OpenCV CSRT tracker) and
streams x_pos / y_pos pixel coordinates as live channels into the
acquisition pipeline. Falls back to a Lissajous figure simulation
when opencv-python is not installed, so the plugin works immediately
without hardware.
- tracker.py: background thread, real camera + sim modes, thread-safe API
- device.py: BaseDevice reading x/y from tracker, wires into engine
- filter.py: custom pixel_to_mm filter (registered in FILTER_CLASSES)
- window.py: floating tool window, live feed, click-to-track ROI selection
- plugin.py: LabPlugin wiring all pieces together, toolbar button,
settings widget, profile save/restore
Also: PluginAction.button_ref_callback lets plugins store a ref to their
toolbar button so they can uncheck it when their window closes.
opencv-python install note added to requirements.txt.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
|
|
Plugins live in plugins/<name>/ with a manifest.json and a LabPlugin
subclass. Enabled/disabled in Settings > Plugins tab; state persists in
plugins/enabled.json and in .labdaq profiles (loading a profile
enables/disables plugins to match). Plugins can contribute toolbar
buttons, BaseDevice instances (auto-wired into acquisition pipeline),
custom signal filter classes, a settings widget, and profile state via
get_save_state/apply_save_state. Load errors now report the exact
failing stage (file not found, class missing, on_load crash).
Includes example plugin skeleton and docs/plugin-development.md.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
|
|
|
|
|
|
|
|
Fixed derived signal saving profile. Renamed Signals>Pipeline to Signas>Channels
and adding/removing channels feature.
|
|
|
|
|
|
|
|
|
|
Including:
- Control panel
- Change status of simulation after devices creation.
- Arduino serial conflict with multiple channels.
- Claude instructions.
- Update to arduino on board code.
|
|
This version contains the profile feature. Allowins users to save the
channels, signals and plots for specific labs.
|
|
|
|
|
|
|